Views: 0 Author: Site Editor Publish Time: 2026-11-20 Origin: Site
Anyone who regularly works in the grinding workshop knows: once the discharge concentration drifts, the grinding fineness can't be kept stable, and downstream flotation and gravity separation are all affected—indicators can collapse on the spot.
Today, starting from frontline practical operation, we'll teach you how to make a quick visual judgment, troubleshoot by priority, and adjust smoothly into place.
Many newcomers, when they encounter a problem, immediately grab a concentration jug and measure repeatedly. In fact, experienced operators first make a preliminary judgment through on-site observation, which can save many detours.
●Look at the discharge port
The slurry is obviously thicker, fluidity deteriorates, discharge is not smooth enough, and deposition easily occurs in the discharge trough. Compared with normal production conditions, the sense of thickness is noticeably enhanced, which often indicates a rising trend in discharge concentration.
●Listen to the mill, watch the current
When the slurry volume is on the high side and the mill load increases, the mill sound may become dull, and the main motor current may also change. If this is accompanied by poor discharge, reduced throughput, and abnormal mill operating sound, be alert to ore accumulation inside the mill or even swelling.
●Look at downstream indicators
If the discharge state is on the thick side while the classification overflow fineness also becomes noticeably coarser, it indicates that the grinding-classification system has already been affected, and further checks on feed, grinding load, and classification status are needed.
In many metal ore ball milling operations, the discharge concentration is commonly around 65%–75%, which can serve as a preliminary on-site reference. However, the actual control value of a concentrator should be based on established process indicators, and water must not be blindly added simply to reach this range.
On-site tip: Visual inspection can only provide a preliminary judgment of the trend; the final determination must be based on actual measurement with a concentration jug. When sampling, take a representative sample at a location where the discharge slurry flows uniformly, stir thoroughly before measurement, and do not skim only the thin surface slurry or take slurry that has already settled in the discharge trough. After each adjustment, try to compare at the same sampling location using the same method, so that you can accurately determine whether the concentration has truly decreased.
The valve being open does not mean water is actually being added
This is the most common and most easily overlooked cause. Many people only look at the valve opening and not the actual water inflow, so they adjust for a long time in vain.
●First check water pressure: Especially during peak water-use periods in the plant area, or when multiple points are drawing water simultaneously nearby, water pressure will drop noticeably. Even if the valve is fully open, the actual water inflow will be greatly reduced.
●Then check the pipeline: Is the filter screen at the front end of the water supply pipe blocked? Has the pipe wall narrowed due to scaling? Concentrators with poor water quality and more impurities should regularly check the water supply filter screen. Once the filter screen is blocked, even if the valve opening remains unchanged, the actual water inflow will drop noticeably. In northern winters, also check for frozen pipe blockages; a quiet drop in water volume is hard to detect immediately.
●After confirming the water path is unobstructed, slightly increase the feed water according to the current supplementary water volume. After each adjustment, record the actual water inflow and the change in discharge concentration. Wait until the mill and classification system are running stably before deciding whether to continue adjusting; do not add a large amount of water all at once.
Supplementary water should preferably be adjusted according to the mill's original water supply regime, and the water supply location must not be arbitrarily changed just to reduce discharge concentration.
When it is necessary to increase supplementary water inside the mill, adjust it in combination with the existing water distribution at the feed end, mill cylinder, and discharge end, to avoid excessive local water addition disrupting the grinding and classification state.
Many times it's not that water is too little, but that ore is too much or too dry
Many people, when encountering high concentration, only stare at the water valve. In fact, a considerable portion of the problem lies on the ore side.
●Verify the feed rate
Check whether the feeder frequency has been adjusted by someone, and whether the bin discharge has become faster because the ore has become drier. If the feed rate rises and the supplementary water volume does not increase accordingly, more solid material enters the mill, and the concentration naturally goes up.
●Check the raw ore moisture
After the rainy season, ore dries out, or when ore from a dry ore stockpile is switched in, the moisture carried in by the raw ore itself decreases. With the dry ore feed rate and external water volume unchanged, the total water entering the mill decreases, and the discharge concentration rises. Therefore, after changing ore sources, changing ore stockpiles, or seasonal changes, don't just stare at the feed water valve; also verify changes in raw ore moisture.
First stabilize the feed rate to a normal value. If ore properties change over the long term, re-match the water-to-ore ratio and fix it; do not rely only on manual adjustment.
The problem is not in the mill, but in the circulating load
In concentrators with closed-circuit grinding, this point is especially easy to overlook.
Many people think that a large return sand volume means high discharge concentration, but the two cannot be directly equated.
In closed-circuit grinding, an abnormal increase in return sand volume raises the mill's circulating load and greatly increases the total material throughput of the mill.
If the feed rate and supplementary water volume are not matched in time, the mill is prone to problems such as high load and poor discharge. Therefore, when discharge concentration remains persistently high, don't just stare at the mill feed water; also check whether the classification equipment has abnormal return sand.
●Focus on the cyclone underflow state Under normal conditions, the underflow usually sprays in an umbrella shape; if the underflow becomes a continuous rope-like stream, it indicates that the sand discharge state has become abnormal. Focus on checking whether the apex is blocked, whether the specification is too small, and whether the feed concentration and pressure are appropriate.
An abnormal underflow state may also be accompanied by reduced classification efficiency and increased return sand load, and further judgment should be made in combination with overflow particle size.
Adjustment method: First check whether the apex is blocked, worn, or of inappropriate specification, then verify the cyclone feed pressure and feed concentration. When the underflow discharges in a rope-like stream, prioritize restoring the normal underflow spray state; do not blindly increase pressure or directly replace with a large-specification apex. After adjustment, observe the underflow shape, return sand volume, and overflow particle size simultaneously.
Note: If a spiral classifier is used, focus on checking the return sand volume, overflow state, overflow weir, and spiral blade operation; the pressure and apex adjustment methods for cyclones cannot be directly applied.
Rule out hard faults of channel blockage
If all the preceding items have been checked and discharge is still not smooth, further check the mill discharge structure. Different types of mills have different troubleshooting priorities:
●Grate ball mill: Focus on checking whether the grate plates and discharge channels are blocked;
●Overflow ball mill: Check whether there is debris blocking the discharge end or whether the discharge channel is obstructed;
Blockage of the screen or trommel screen at the discharge end can also cause the entire discharge system to be unsmooth wood chips, iron wire, and broken liner fragments carried in the ore getting stuck in the discharge channel are very common causes. After the discharge channel is blocked, slurry discharge is obstructed, and slurry accumulates in the mill, which easily causes increased mill load and reduced discharge volume, and in severe cases may lead to swelling.
This situation is generally accompanied by a noticeable reduction in discharge volume and an increasingly dull mill sound. Once discovered, stop the machine promptly to inspect and clear the blockage.
Add water slowly and check frequently; never do it all at once
Adding a large amount of water at one time does reduce the discharge concentration, but the grinding fineness will directly run coarse, and downstream flotation indicators will collapse on the spot.
After each adjustment, record the water supply volume, discharge concentration, and classification overflow fineness, and wait until the grinding-classification system runs stably before judging whether to continue adjusting.
The adjustment range should be based on the principle of not causing obvious fluctuations in fineness; stability is more important than speed.
Concentration is the means, fineness is the goal
Reducing discharge concentration is not the ultimate goal; stabilizing qualified classification overflow fineness is.
During adjustment, verify simultaneously:
If concentration drops and classification overflow fineness still meets production requirements, the adjustment direction is correct;
If concentration comes down but fineness also runs coarse, dial back part of the water volume to find the balance point between the two.
Never ruin the core fineness indicator just to hit a concentration number—the loss outweighs the gain.
Strengthen night-shift inspections; don't wait until it's out of control to remedy it
Night shift is a high-incidence period for discharge concentration fluctuations: water pressure fluctuations, feed deviation, and reduced inspection frequency can all let concentration quietly rise, and by the time the day shift discovers it, it has already been chaotic for several hours.
Night shift should strengthen discharge concentration inspections, especially paying attention to periods when feed rate, feed water pressure, and equipment operating status change. When abnormal discharge conditions are found, sample and measure promptly to avoid long-term operation under faulty conditions.
When encountering high discharge concentration, follow this sequence step by step to avoid detours:
Check feed water: Verify water pressure, valve, filter screen, and actual water inflow; confirm whether water is truly being added
Check feed: Verify feed rate, raw ore moisture, and feed stability; confirm whether solid material volume has increased and whether water carried in by raw ore has decreased
Check classification: Check return sand volume, cyclone underflow state, and overflow fineness; confirm whether circulating load is abnormal and whether classification is operating normally
Check equipment: Check grate plates/discharge channels and discharge screens; confirm whether there is discharge obstruction
Fine-tune water: Slightly adjust supplementary water, track discharge concentration and overflow fineness, and confirm whether it has returned to normal production state
When ball mill discharge concentration is high, don't rush to open the water valve wide.
First check whether water is truly being added, then see whether ore volume and raw ore moisture have changed, and finally check return sand and discharge equipment. Once the cause is identified, then slightly adjust the water volume while keeping an eye on classification overflow fineness.
Reducing concentration is not simply adding water; stabilizing the grinding-classification system is the ultimate goal.
content is empty!